14092_GAN_UF_Interior_ksobon Error Report (11/11/2016 12:47:11 PM)

Error message
Elements
Cuts on concrete members are ignored. GA - ArchStructure : Structural Framing : Precast-Rectangular Beam : 16RB32 : id 2324745
GA - ArchStructure : Structural Columns : Concrete-Rectangular-Column : 18 x 18 : id 2325239
Highlighted elements are joined but do not intersect. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 18" : id 592453
GA - InteriorWalls : Walls : Basic Wall : F410-GYP-3 5/8 : id 3540762
Highlighted elements are joined but do not intersect. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 18" : id 954150
GA - ArchStructure : Floors : Floor : Generic - 12" - Mark CON-102 : id 1813540
Highlighted elements are joined but do not intersect. GA - InteriorWalls : Walls : Basic Wall : E200-Insulation : id 1564555
GA - ExteriorWalls : Floors : Floor : ROF-101 Insulation roof 4" min : id 3550241
Highlighted elements are joined but do not intersect. GA - ArchStructure : Floors : Floor : Generic - 12" - Mark CON-102 : id 1813540
GA - Ceilings : Ceilings : Compound Ceiling : CLG-109 Painted GWB Resilient Sound Barrier Suspended : id 2829395
Highlighted elements are joined but do not intersect. GA - ArchStructure : Floors : Floor : Generic - 12" - Mark CON-102 : id 1813540
GA - InteriorWalls : Walls : Basic Wall : F410-GYP-3 5/8 : id 3214244
Highlighted elements are joined but do not intersect. GA - ArchStructure : Floors : Floor : Generic - 14" : id 1813669
GA - Ceilings : Ceilings : Compound Ceiling : CLG-103 Acoustic Spray-on Insulation : id 3024511
Highlighted elements are joined but do not intersect. GA - ArchStructure : Floors : Floor : Generic - 12" : id 2523832
GA - InteriorWalls : Walls : Basic Wall : F410-GYP-3 5/8 : id 3214244
Highlighted elements are joined but do not intersect. GA - ArchStructure : Floors : Floor : Generic - 12" : id 2523832
GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3408193
Highlighted elements are joined but do not intersect. GA - Floors : Floors : Floor : Generic - 1" : id 2523850
GA - InteriorWalls : Generic Models : SPC BathroomStallADA : Regular stall 2 : id 3519139
Highlighted elements are joined but do not intersect. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3408193
GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 3540771
Highlighted elements are joined but do not intersect. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3408193
(Slab deflections : Str. alternate solution) : GA - ArchStructure : Floors : Floor : Generic - 8" : id 3651900
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Section: LONGITUDINAL SECTION (OFF GRIDLINE B)" : Room Tags : ANO_Room Tag : Room Tag Number : id 879175
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: SCW - LOBBY E2" : Room Tags : ANO_Room Tag Narrow 3_64 : Name + Area : id 1951079
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: SCW - LOBBY E2" : Room Tags : ANO_Room Tag Narrow 3_64 : Name + Area : id 1951086
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 02 PLN_WORKSHOP" : Room Tags : ANO_Room Tag Presentation : Default : id 2285928
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw - 01 pln life safety areas" : Room Tags : ANO_Room Tag : Room Tag : id 2326732
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw - 04 pln life safety areas" : Room Tags : ANO_Occupancy Tag : OccUseTag : id 2327248
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw - 04 pln life safety areas" : Room Tags : ANO_Room Tag Narrow : Room Tag : id 2327279
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-02 pln_cs_01" : Room Tags : ANO_Room Tag Presentation : Default : id 2437756
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-02 pln_cs_02" : Room Tags : ANO_Room Tag Presentation : Default : id 2439392
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-04 pln_cs_01" : Room Tags : ANO_Room Tag Presentation : Default : id 2439640
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-04 pln_cs_01" : Room Tags : ANO_Room Tag Presentation : Default : id 2439641
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-04 pln_cs_02" : Room Tags : ANO_Room Tag Presentation : Default : id 2440185
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-04 pln_cs_02" : Room Tags : ANO_Room Tag Presentation : Default : id 2440186
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-04 pln_cs_03" : Room Tags : ANO_Room Tag Presentation : Default : id 2440616
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-04 pln_cs_03" : Room Tags : ANO_Room Tag Presentation : Default : id 2440617
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-04 pln_cs_04" : Room Tags : ANO_Room Tag Presentation : Default : id 2441921
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-04 pln_cs_04" : Room Tags : ANO_Room Tag Presentation : Default : id 2441922
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-04 pln_cs_05" : Room Tags : ANO_Room Tag Presentation : Default : id 2442330
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: mw-04 pln_cs_05" : Room Tags : ANO_Room Tag Presentation : Default : id 2442331
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 PLP_ENLARGED B" : Room Tags : ANO_Room Tag : Room Tag Number : id 2628785
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 PLP_ENLARGED B" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 2628815
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 02 PLP_ENLARGED B" : Room Tags : ANO_Room Tag Presentation : Default : id 2670021
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 PLN ZOOM FLEX OFFICE SUITE" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 2954002
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 pln_mw egress stairs" : Room Tags : ANO_Room Tag Narrow 3_64 : Name + Area : id 2992021
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 pln_mw egress stairs" : Room Tags : ANO_Room Tag Narrow 3_64 : Name + Area : id 2992023
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 PLN - FINISH" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 3215077
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: ai 04 pln" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 3354579
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 PLN Coordination" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 3695137
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 PLN - AV coordination 01" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 3854793
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 PLN - AV coordination 02" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 3855530
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 pln_mw" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 3890184
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Reflected Ceiling Plan: LEVEL 04" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 4021829
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Section: SECTION DETAIL - INTERIOR GLAZING TYPE 1A" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 4877000
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 03 PLN_MONUMENTAL STAIR" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 4877876
Room Tag is outside of its Room. Enable Leader or move Room Tag within its Room. View "Floor Plan: 04 PLN_MONUMENTAL STAIR" : Room Tags : ANO_Room Tag Narrow : Room Tag Number : id 4970020
Multiple Rooms are in the same enclosed region. The correct area and perimeter will be assigned to one Room and the others will display "Redundant Room." You should separate the regions, delete the extra Rooms, or move them into different regions. Workset1 : Rooms : Room : FRESHMAN ADVISING RECEPTION AND WAITING 231 - Number 231 : id 709635
Workset1 : Rooms : Room : CIRC 238 - Number 238 : id 793054
Multiple Rooms are in the same enclosed region. The correct area and perimeter will be assigned to one Room and the others will display "Redundant Room." You should separate the regions, delete the extra Rooms, or move them into different regions. Workset1 : Rooms : Room : CIRCULATION 427 - Number 427 : id 2938465
Workset1 : Rooms : Room : CIRCULATION 401 - Number 401 : id 2938845
Multiple Rooms are in the same enclosed region. The correct area and perimeter will be assigned to one Room and the others will display "Redundant Room." You should separate the regions, delete the extra Rooms, or move them into different regions. (Annex : Option 2) : GA - InteriorWalls : Rooms : Room : CpE - ADV. OFFICE 483 - Number 483 : id 5211189
(Annex : Option 2) : GA - InteriorWalls : Rooms : Room : CpE - STAFF OFF 488 - Number 488 : id 5211194
Multiple Rooms are in the same enclosed region. The correct area and perimeter will be assigned to one Room and the others will display "Redundant Room." You should separate the regions, delete the extra Rooms, or move them into different regions. (Annex : Option 2) : GA - InteriorWalls : Rooms : Room : CpE - DESIGN STUDIO 489 - Number 489 : id 5211195
(Annex : Option 2) : GA - InteriorWalls : Rooms : Room : COMPUTER ENGINEERING - DESIGN STUDIO 1 490 - Number 490 : id 5211196
Multiple Rooms are in the same enclosed region. The correct area and perimeter will be assigned to one Room and the others will display "Redundant Room." You should separate the regions, delete the extra Rooms, or move them into different regions. (Annex : Option 2) : GA - InteriorWalls : Rooms : Room : CIRCULATION 493 - Number 493 : id 5211200
(Annex : Option 2) : GA - InteriorWalls : Rooms : Room : COLLAB. SPACE 498 - Number 498 : id 5211311
Multiple Rooms are in the same enclosed region. The correct area and perimeter will be assigned to one Room and the others will display "Redundant Room." You should separate the regions, delete the extra Rooms, or move them into different regions. (Annex : Option 2) : GA - InteriorWalls : Rooms : Room : CpE RECEPTION 492 - Number 492 : id 5211198
(Annex : Option 2) : GA - InteriorWalls : Rooms : Room : CpE - COLLAB. SPACE 497 - Number 497 : id 5211310
(Annex : Option 2) : GA - InteriorWalls : Rooms : Room : CpE - SPECIAL PROJECTS LAB 499 - Number 499 : id 5211321
The highlighted column can't maintain attachment to the target. It will be treated as unattached until it can intersect. GA - Louvers : Structural Columns : S Shapes-Column : S5X10 : id 4196356
GA - Louvers : Structural Framing : HSS-Hollow Structural Section : HSS5X5X1/8 : id 4451975
Could not create Wall Sweep. Sweep position is outside of its wall. Please check sweep parameters. (Offices 4th floor : Option 3) : Workset1 : Wall Sweeps : Wall Sweep : Wall Base - RUB-101 : id 5273345
Could not create Wall Sweep. Sweep position is outside of its wall. Please check sweep parameters. (Offices 4th floor : Option 3) : Workset1 : Wall Sweeps : Wall Sweep : Wall Base - RUB-101 : id 5273346
Rectangular opening doesn't cut its host. GA - InteriorWalls : Rectangular Straight Wall Opening : Rectangular Straight Wall Opening : id 3539707
Design Option ' ELI/EII OFFICE SUITE : Option 3 ' cannot reference Design Option ' Immersive Telepresence Room : Option 1 - TX9000 '. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Curtain Panels : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309265
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5286817
Design Option ' ELI/EII OFFICE SUITE : Option 3 ' cannot reference Design Option ' Immersive Telepresence Room : Option 1 - TX9000 '. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Curtain Panels : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309266
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5286817
Design Option ' Immersive Telepresence Room : Option 1 - TX9000 ' cannot reference Design Option ' ELI/EII OFFICE SUITE : Option 3 '. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309239
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326974
Design Option ' Main Model ' cannot reference Design Option ' ELI/EII OFFICE SUITE : Option 2 '. GA - InteriorWalls : : Model Lines : id 1942620
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : Generic 6" : id 5318810
Design Option ' Main Model ' cannot reference Design Option ' ELI/EII OFFICE SUITE : Option 2 '. GA - InteriorWalls : : Model Lines : id 5180974
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326875
Design Option ' Main Model ' cannot reference Design Option ' ELI/EII OFFICE SUITE : Option 3 '. GA - InteriorWalls : : Model Lines : id 5180974
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326972
Area separation line is slightly off axis and may cause inaccuracies. Workset1 : : Model Lines : id 560693
Area separation line is slightly off axis and may cause inaccuracies. Workset1 : : Model Lines : id 560695
Area separation line is slightly off axis and may cause inaccuracies. Workset1 : : Model Lines : id 1049032
Area separation line is slightly off axis and may cause inaccuracies. GA - InteriorWalls : : Model Lines : id 2290822
Area separation line is slightly off axis and may cause inaccuracies. GA - InteriorWalls : : Model Lines : id 2294107
Area separation line is slightly off axis and may cause inaccuracies. GA - InteriorWalls : : Model Lines : id 2294126
Area separation line is slightly off axis and may cause inaccuracies. GA - InteriorWalls : : Model Lines : id 2294248
Area separation line is slightly off axis and may cause inaccuracies. GA - InteriorWalls : : Model Lines : id 2295272
Area separation line is slightly off axis and may cause inaccuracies. GA - InteriorWalls : : Model Lines : id 2302426
Area separation line is slightly off axis and may cause inaccuracies. Workset1 : : Model Lines : id 2790828
Area separation line is slightly off axis and may cause inaccuracies. Workset1 : : Model Lines : id 2801883
Area separation line is slightly off axis and may cause inaccuracies. Workset1 : : Model Lines : id 2801931
Room separation line is slightly off axis and may cause inaccuracies. Workset1 : : Model Lines : id 2953589
Line in Sketch is slightly off axis and may cause inaccuracies. GA - Ceilings : : Model Lines : id 2594702
GA - Ceilings : Ceilings : Compound Ceiling : CLG-107 ACT (2X4) : id 2594250
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '02 PLP_ENLARGED A CpE Layout'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : CIRCULATION 218 - Number 218 : id 827133
View "Floor Plan: 02 PLP_ENLARGED A CpE Layout" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5356251
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '02 PLP_ENLARGED A CpE Layout'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : COLLAB 224 - Number 224 : id 2249262
View "Floor Plan: 02 PLP_ENLARGED A CpE Layout" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5356255
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : SEMMOTO GLOBAL TELECONFERENCING FACILITY 411 - Number 411 : id 757894
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346470
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- DEV. OFFICER OFF. (2) 425 - Number 425 : id 758185
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346473
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- DEV. OFFICER OFF. 414 - Number 414 : id 763528
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346474
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- MTG. RM. 424 - Number 424 : id 763531
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346475
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- DIRECTOR'S OFF. 426 - Number 426 : id 763534
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346476
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- DEV. DIR. OFF. 416 - Number 416 : id 763537
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346477
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- ASS. DIR. OFF. (1) 413 - Number 413 : id 763540
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346478
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- VISITING PARTNER OFF. (1) 415 - Number 415 : id 763901
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346479
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX OFFICE RECEPTION 417 - Number 417 : id 1159805
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346481
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. GA - InteriorWalls : Rooms : Room : AV 459 - Number 459 : id 5169919
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346487
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 1'. To resolve, select the Main Model Room and use the Add to Design Option Set command. GA - InteriorWalls : Rooms : Room : COLLAB 460 - Number 460 : id 5181021
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346488
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : SEMMOTO GLOBAL TELECONFERENCING FACILITY 411 - Number 411 : id 757894
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345700
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- DEV. OFFICER OFF. (2) 425 - Number 425 : id 758185
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345703
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- DEV. OFFICER OFF. 414 - Number 414 : id 763528
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345704
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- MTG. RM. 424 - Number 424 : id 763531
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345705
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- DIRECTOR'S OFF. 426 - Number 426 : id 763534
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345706
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- DEV. DIR. OFF. 416 - Number 416 : id 763537
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345707
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- ASS. DIR. OFF. (1) 413 - Number 413 : id 763540
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345708
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- VISITING PARTNER OFF. (1) 415 - Number 415 : id 763901
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345709
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX OFFICE RECEPTION 417 - Number 417 : id 1159805
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345711
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. GA - InteriorWalls : Rooms : Room : AV 459 - Number 459 : id 5169919
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345717
Option Conflict between Rooms. Room boundary in the Main Model differs from the apparent boundary in view '04 PLP_ENLARGED A ELI/EII 2'. To resolve, select the Main Model Room and use the Add to Design Option Set command. GA - InteriorWalls : Rooms : Room : COLLAB 460 - Number 460 : id 5181021
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345718
Option Conflict between Rooms. Room in Option 'ELI/EII OFFICE SUITE : Option 4' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : SEMMOTO GLOBAL TELECONFERENCING FACILITY 411 - Number 411 : id 757894
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Rooms : Room : Room 568 - Number 568 : id 5330025
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345725
Option Conflict between Rooms. Room in Option 'ELI/EII OFFICE SUITE : Option 4' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : SEMMOTO GLOBAL TELECONFERENCING FACILITY 411 - Number 411 : id 757894
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Rooms : Room : Room 569 - Number 569 : id 5330028
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345726
Option Conflict between Rooms. Room in Option 'ELI/EII OFFICE SUITE : Option 4' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- DEV. OFFICER OFF. (2) 425 - Number 425 : id 758185
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Rooms : Room : Room 572 - Number 572 : id 5330334
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345728
Option Conflict between Rooms. Room in Option 'ELI/EII OFFICE SUITE : Option 4' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- DEV. OFFICER OFF. 414 - Number 414 : id 763528
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Rooms : Room : Room 570 - Number 570 : id 5330031
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345727
Option Conflict between Rooms. Room in Option 'ELI/EII OFFICE SUITE : Option 4' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FLEX- MTG. RM. 424 - Number 424 : id 763531
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Rooms : Room : Room 573 - Number 573 : id 5330480
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345729
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (1) 409 - Number 409 : id 757885
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 551 - Number 551 : id 5276312
View "Floor Plan: 04 PLN" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5276313
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (1) 409 - Number 409 : id 757885
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 551 - Number 551 : id 5276312
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345724
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (1) 409 - Number 409 : id 757885
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 551 - Number 551 : id 5276312
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346494
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (1) 409 - Number 409 : id 757885
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 551 - Number 551 : id 5276312
View "Floor Plan: 04 PLP_ENLARGED A FAC OFF" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5349853
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (2) 410 - Number 410 : id 757888
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 550 - Number 550 : id 5276309
View "Floor Plan: 04 PLN" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5276310
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (2) 410 - Number 410 : id 757888
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 550 - Number 550 : id 5276309
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345723
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (2) 410 - Number 410 : id 757888
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 550 - Number 550 : id 5276309
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346493
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (2) 410 - Number 410 : id 757888
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 550 - Number 550 : id 5276309
View "Floor Plan: 04 PLP_ENLARGED A FAC OFF" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5349852
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. 421 - Number 421 : id 757891
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 549 - Number 549 : id 5276306
View "Floor Plan: 04 PLN" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5276307
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. 421 - Number 421 : id 757891
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 549 - Number 549 : id 5276306
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345722
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. 421 - Number 421 : id 757891
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 549 - Number 549 : id 5276306
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346492
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. 421 - Number 421 : id 757891
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 549 - Number 549 : id 5276306
View "Floor Plan: 04 PLP_ENLARGED A FAC OFF" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5349851
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (4) 429 - Number 429 : id 757897
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 546 - Number 546 : id 5276014
View "Floor Plan: 04 PLN" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5276015
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (4) 429 - Number 429 : id 757897
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 546 - Number 546 : id 5276014
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345719
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (4) 429 - Number 429 : id 757897
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 546 - Number 546 : id 5276014
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346489
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF. (4) 429 - Number 429 : id 757897
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 546 - Number 546 : id 5276014
View "Floor Plan: 04 PLP_ENLARGED A FAC OFF" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5349848
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF 428 - Number 428 : id 2253847
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 547 - Number 547 : id 5276017
View "Floor Plan: 04 PLN" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5276018
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF 428 - Number 428 : id 2253847
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 547 - Number 547 : id 5276017
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345720
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF 428 - Number 428 : id 2253847
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 547 - Number 547 : id 5276017
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346490
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF 428 - Number 428 : id 2253847
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 547 - Number 547 : id 5276017
View "Floor Plan: 04 PLP_ENLARGED A FAC OFF" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5349849
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF 422 - Number 422 : id 2253850
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 548 - Number 548 : id 5276020
View "Floor Plan: 04 PLN" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5276021
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF 422 - Number 422 : id 2253850
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 548 - Number 548 : id 5276020
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 2" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5345721
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF 422 - Number 422 : id 2253850
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 548 - Number 548 : id 5276020
View "Floor Plan: 04 PLP_ENLARGED A ELI/EII 1" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5346491
Option Conflict between Rooms. Room in Option 'Offices 4th floor : Option 3 (primary)' overlaps Room in the Main Model. To resolve, select the Main Model Room and use the Add to Design Option Set command. Workset1 : Rooms : Room : FAC. OFF 422 - Number 422 : id 2253850
(Offices 4th floor : Option 3) : Workset1 : Rooms : Room : Room 548 - Number 548 : id 5276020
View "Floor Plan: 04 PLP_ENLARGED A FAC OFF" : Room Tags : Gi_Room Tag : Room Tag With Area : id 5349850
Two elements were not automatically joined because one or both is not editable. GA - InteriorWalls : Walls : Basic Wall : D420-GSL-4-2xGYP : id 975539
GA - InteriorWalls : Walls : Basic Wall : F410-GYP-3 5/8 : id 3540768
Two elements were not automatically joined because one or both is not editable. GA - InteriorWalls : Curtain Panels : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 3624963
GA - InteriorWalls : Curtain Panels : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5043817
Two elements were not automatically joined because one or both is not editable. GA - InteriorWalls : Curtain Panels : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 3624965
GA - InteriorWalls : Curtain Panels : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5043817
Two elements were not automatically joined because one or both is not editable. GA - InteriorWalls : Curtain Panels : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 3624975
GA - InteriorWalls : Curtain Panels : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5043834
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3267912
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3267915
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3267926
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3267939
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3268117
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3268118
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3268119
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3268120
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3268319
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3268320
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3268752
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3268934
Type : GA - Ceilings : Model Groups : Model Group : facade-option2 : id 3267344
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3277935
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3277938
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3277949
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3277962
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3278140
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3278141
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3278142
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3278143
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3278342
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3278343
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3278776
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3278971
Type : GA - Ceilings : Model Groups : Model Group : Group 1 : id 3274973
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3282626
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3282629
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3282640
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3282653
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3282831
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3282832
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3282833
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3282834
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3283033
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3283034
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3283377
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3283566
Type : GA - Ceilings : Model Groups : Model Group : Group 2 : id 3282058
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3294408
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3294411
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3294422
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3294435
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3294613
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3294614
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3294615
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3294616
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3294815
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3294816
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3295248
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3295430
Type : GA - Ceilings : Model Groups : Model Group : Group 10 : id 3293840
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3304318
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3304321
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3304332
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3304345
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3304523
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3304524
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3304525
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3304526
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3304725
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3304726
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3305159
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3305354
Type : GA - Ceilings : Model Groups : Model Group : Group 11 : id 3301414
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3308990
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3308993
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3309004
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3309017
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3309195
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3309196
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3309197
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3309198
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3309397
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3309398
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3309741
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Some panels in this curtain system are slightly malformed. The problem is most likely ignorable. This problem usually occurs when a panel or parts of a panel have been divided so that they are very narrow. To better see the malformed panels, temporarily hide the mullion category and set display of lines to "thin lines" (using the command on the view menu). GA - Ceilings : Curtain Panels : System Panel : Glazed : id 3309930
Type : GA - Ceilings : Model Groups : Model Group : Group 12 : id 3308422
Highlighted room separation lines overlap. One of them may be ignored when Revit finds room boundaries. Delete one of the lines. GA - InteriorWalls : : Model Lines : id 4067508
GA - InteriorWalls : : Model Lines : id 5169972
Highlighted room separation lines overlap. One of them may be ignored when Revit finds room boundaries. Delete one of the lines. GA - InteriorWalls : : Model Lines : id 4067542
GA - InteriorWalls : : Model Lines : id 5169975
Highlighted room separation lines overlap. One of them may be ignored when Revit finds room boundaries. Delete one of the lines. GA - Floors : : Model Lines : id 4494678
GA - Floors : : Model Lines : id 5049969
Highlighted room separation lines overlap. One of them may be ignored when Revit finds room boundaries. Delete one of the lines. GA - Floors : : Model Lines : id 4494678
GA - InteriorWalls : : Model Lines : id 5170310
Highlighted room separation lines overlap. One of them may be ignored when Revit finds room boundaries. Delete one of the lines. GA - Floors : : Model Lines : id 5049969
GA - InteriorWalls : : Model Lines : id 5170310
Highlighted room separation lines overlap. One of them may be ignored when Revit finds room boundaries. Delete one of the lines. (Annex : Option 2) : GA - InteriorWalls : : Model Lines : id 5236377
Workset1 : : Model Lines : id 5441550
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 2294124
GA - InteriorWalls : : Model Lines : id 2294125
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 2298342
GA - InteriorWalls : : Model Lines : id 5160254
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 2298351
GA - InteriorWalls : : Model Lines : id 2299250
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 2298352
GA - InteriorWalls : : Model Lines : id 2299250
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 2302052
GA - InteriorWalls : : Model Lines : id 5161354
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 2302057
GA - InteriorWalls : : Model Lines : id 5161249
Highlighted lines overlap. Lines may not form closed loops. Workset1 : : Model Lines : id 2778729
Workset1 : : Model Lines : id 2779349
Highlighted lines overlap. Lines may not form closed loops. Workset1 : : Model Lines : id 2778729
Workset1 : : Model Lines : id 2779769
Highlighted lines overlap. Lines may not form closed loops. Workset1 : : Model Lines : id 2790855
Workset1 : : Model Lines : id 2798851
Highlighted lines overlap. Lines may not form closed loops. Workset1 : : Model Lines : id 2790866
GA - InteriorWalls : : Model Lines : id 4859636
Highlighted lines overlap. Lines may not form closed loops. Workset1 : : Model Lines : id 2808030
Workset1 : : Model Lines : id 2808841
Highlighted lines overlap. Lines may not form closed loops. GA - StairsRailings : : Model Lines : id 4485689
GA - StairsRailings : : Model Lines : id 4485701
GA - StairsRailings : Railings : Railing : Guardrail - Pipe Vertical : id 4485682
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5158115
GA - InteriorWalls : : Model Lines : id 5158197
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5158197
GA - InteriorWalls : : Model Lines : id 5158229
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5160183
GA - InteriorWalls : : Model Lines : id 5160219
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5160219
GA - InteriorWalls : : Model Lines : id 5160255
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5161226
GA - InteriorWalls : : Model Lines : id 5161250
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5161226
GA - InteriorWalls : : Model Lines : id 5161276
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5161315
GA - InteriorWalls : : Model Lines : id 5161336
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5161336
GA - InteriorWalls : : Model Lines : id 5161355
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5162532
GA - InteriorWalls : : Model Lines : id 5182971
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5162555
GA - InteriorWalls : : Model Lines : id 5162574
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5165055
GA - InteriorWalls : : Model Lines : id 5165482
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5165346
GA - InteriorWalls : : Model Lines : id 5165459
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5165423
GA - InteriorWalls : : Model Lines : id 5165457
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5165423
GA - InteriorWalls : : Model Lines : id 5165484
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5165924
GA - InteriorWalls : : Model Lines : id 5165945
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5165945
GA - InteriorWalls : : Model Lines : id 5165990
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5166211
GA - InteriorWalls : : Model Lines : id 5166230
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5166230
GA - InteriorWalls : : Model Lines : id 5166247
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5166589
GA - InteriorWalls : : Model Lines : id 5167020
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5167292
GA - InteriorWalls : : Model Lines : id 5167313
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5167313
GA - InteriorWalls : : Model Lines : id 5167334
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5167402
GA - InteriorWalls : : Model Lines : id 5168082
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5167405
GA - InteriorWalls : : Model Lines : id 5168085
Highlighted lines overlap. Lines may not form closed loops. GA - InteriorWalls : : Model Lines : id 5167623
GA - InteriorWalls : : Model Lines : id 5168085
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1659031
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5438299
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1659032
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5438300
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Table : 66" x 18" : id 1659033
Workset1 : Furniture : FRN_Office Table : 66" x 18" : id 5438301
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 1704473
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438314
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1722840
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432590
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1722842
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432591
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1761838
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5438315
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1761839
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5438316
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Table : 66" x 18" : id 1761840
Workset1 : Furniture : FRN_Office Table : 66" x 18" : id 5438317
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936216
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432592
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936217
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432593
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936218
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432594
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936219
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432595
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936224
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432596
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936226
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432597
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936232
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432598
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936233
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432599
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936234
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432600
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936235
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432601
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936240
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432602
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936241
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432603
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936242
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432604
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936243
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432605
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936248
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432606
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936249
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432607
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936250
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432608
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936251
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432609
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936256
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432610
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936257
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432611
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936258
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432612
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936259
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432613
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936264
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432614
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936265
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432615
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936266
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432616
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936267
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432617
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936272
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432618
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936273
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432619
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936274
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432620
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936275
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432621
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936280
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432622
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936281
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432623
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936282
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432624
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936283
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432625
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936288
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432626
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936289
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432627
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936290
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432628
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936291
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432629
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936296
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432630
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936297
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432631
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936298
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432632
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936299
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432633
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936304
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432634
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936305
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432635
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936306
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432636
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936307
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432637
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936312
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432638
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936313
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432639
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936314
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432640
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936315
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432641
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936320
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432642
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936321
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432643
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936322
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432644
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936323
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432645
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936336
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432646
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936337
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432647
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936338
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432648
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936339
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432649
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936355
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432650
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936356
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432651
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 1936357
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432652
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 1936358
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432653
There are identical instances in the same place. This will result in double counting in schedules. (Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339538
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339885
There are identical instances in the same place. This will result in double counting in schedules. (Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339540
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339887
There are identical instances in the same place. This will result in double counting in schedules. (Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339542
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339889
There are identical instances in the same place. This will result in double counting in schedules. (Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339544
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339891
There are identical instances in the same place. This will result in double counting in schedules. (Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339546
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339893
There are identical instances in the same place. This will result in double counting in schedules. (Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339548
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339895
There are identical instances in the same place. This will result in double counting in schedules. (Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339550
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : M_Concrete-Round-Column : 22" : id 3339901
There are identical instances in the same place. This will result in double counting in schedules. (Columns : Option 2) : GA - InteriorWalls : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3339851
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3340298
There are identical instances in the same place. This will result in double counting in schedules. (Columns : Option 2) : GA - InteriorWalls : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3339857
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3340300
There are identical instances in the same place. This will result in double counting in schedules. (Columns : Option 2) : GA - InteriorWalls : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3339881
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3340302
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588036
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438318
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588037
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438319
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588038
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438320
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588039
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438321
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588040
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438322
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588041
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438323
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588042
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438324
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588043
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438325
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588044
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438326
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588045
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438327
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588046
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438328
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588321
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438329
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3588373
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438330
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Filing Cabinet : 30" W x 30" H x 18" D : id 3672709
Workset1 : Furniture : FRN_Filing Cabinet : 30" W x 30" H x 18" D : id 5438331
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Filing Cabinet : 30" W x 30" H x 18" D : id 3672710
Workset1 : Furniture : FRN_Filing Cabinet : 30" W x 30" H x 18" D : id 5438332
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 3691810
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432654
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 3691811
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432655
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 3691812
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432656
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 3691813
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432657
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 3691818
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432658
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 3691819
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432659
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 3691820
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432660
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 3691821
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432661
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3692518
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438333
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3692519
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438334
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3692520
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438335
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3692521
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438336
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3692522
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438337
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3692523
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438338
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3692524
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438339
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3692540
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438340
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : Chair-Breuer : Chair-Breuer : id 3692541
Workset1 : Furniture : Chair-Breuer : Chair-Breuer : id 5438341
There are identical instances in the same place. This will result in double counting in schedules. GA - InteriorWalls : Ceilings : Compound Ceiling : CLG-108 Painted GWB : id 4069169
GA - InteriorWalls : Ceilings : Compound Ceiling : CLG-108 Painted GWB : id 4069177
There are identical instances in the same place. This will result in double counting in schedules. GA - InteriorWalls : Ceilings : Compound Ceiling : CLG-108 Painted GWB : id 4069169
GA - InteriorWalls : Ceilings : Compound Ceiling : CLG-108 Painted GWB : id 4069186
There are identical instances in the same place. This will result in double counting in schedules. GA - InteriorWalls : Ceilings : Compound Ceiling : CLG-108 Painted GWB : id 4069177
GA - InteriorWalls : Ceilings : Compound Ceiling : CLG-108 Painted GWB : id 4069186
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 4309206
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432662
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 4309207
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432663
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 4309208
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432664
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 4309213
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432665
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 4309214
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432666
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 4309215
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5432667
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 4309216
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432668
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 4309217
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5432669
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Desk : 50" x 30" : id 5312707
Workset1 : Furniture : FRN_Office Desk : 50" x 30" : id 5438342
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Chair : Task Chair : id 5312708
Workset1 : Furniture : FRN_Office Chair : Task Chair : id 5438343
There are identical instances in the same place. This will result in double counting in schedules. GA - Furniture : Furniture : FRN_Office Table : 66" x 18" : id 5312709
Workset1 : Furniture : FRN_Office Table : 66" x 18" : id 5438344
There are identical instances in the same place. This will result in double counting in schedules. You can tab-select one of the overlapping elements to exclude it from the group instance. (Columns : Option 1) : GA - ArchStructure : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3179463
(BIOTECH : MicroInst_Option 1) : GA - Ceilings : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3291138
There are identical instances in the same place. This will result in double counting in schedules. You can tab-select one of the overlapping elements to exclude it from the group instance. (Columns : Option 1) : GA - ArchStructure : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3180103
(BIOTECH : MicroInst_Option 1) : GA - Ceilings : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3291136
There are identical instances in the same place. This will result in double counting in schedules. You can tab-select one of the overlapping elements to exclude it from the group instance. (Columns : Option 1) : GA - ArchStructure : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3180103
(BIOTECH : West_Option 2) : GA - Ceilings : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3291180
There are identical instances in the same place. This will result in double counting in schedules. You can tab-select one of the overlapping elements to exclude it from the group instance. (BIOTECH : MicroInst_Option 1) : GA - Ceilings : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3291138
(Columns : Option 2) : GA - InteriorWalls : Structural Columns : Concrete-Rectangular-Column : 26 x 26 : id 3340855
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 18" : id 592369
GA - InteriorWalls : : Model Lines : id 4065940
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 18" : id 592453
GA - InteriorWalls : : Model Lines : id 4065507
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 18" : id 592454
GA - ExteriorWalls : : Model Lines : id 3512279
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : Walls : Basic Wall : D420-GSL-4-2xGYP : id 975539
Workset1 : : Model Lines : id 2581644
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 1858780
GA - InteriorWalls : : Model Lines : id 5168337
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 1858780
GA - InteriorWalls : : Model Lines : id 5169214
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 1858780
GA - InteriorWalls : : Model Lines : id 5169462
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 1858780
GA - InteriorWalls : : Model Lines : id 5170003
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 1858780
GA - InteriorWalls : : Model Lines : id 5170261
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 1942620
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5285630
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 1942620
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5285700
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 1942620
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5285940
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 1942620
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5286507
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 1942620
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5286817
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 1942620
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : Generic 6" : id 5291348
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005177
GA - InteriorWalls : : Model Lines : id 2286579
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005178
GA - InteriorWalls : : Model Lines : id 2286593
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005179
GA - InteriorWalls : : Model Lines : id 2286591
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2155195
GA - InteriorWalls : : Model Lines : id 4540149
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 2249181
GA - InteriorWalls : Walls : Basic Wall : D420-GSL-4-2xGYP : id 3540763
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 2249355
(Annex : Option 1) : GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5210515
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 2250291
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5339049
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 2250844
GA - InteriorWalls : Walls : Basic Wall : D420-GSL-4-2xGYP : id 3540720
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 2250844
GA - InteriorWalls : Walls : Basic Wall : D420-GSL-4-2xGYP : id 3540727
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. Workset1 : : Model Lines : id 2561259
GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 3404847
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. Workset1 : : Model Lines : id 2561433
GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 3404846
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. Workset1 : : Model Lines : id 2808279
GA - InteriorWalls : Walls : Basic Wall : F410-GYP-3 5/8 : id 4213350
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. Workset1 : : Model Lines : id 2953153
GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4344883
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. Workset1 : : Model Lines : id 2953685
GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4166762
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 3404848
GA - ExteriorWalls : : Model Lines : id 3404868
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : : Model Lines : id 3404866
GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 3404870
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : : Model Lines : id 3404867
GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 3404871
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3408194
GA - InteriorWalls : : Model Lines : id 5168587
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3408194
GA - InteriorWalls : : Model Lines : id 5169284
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3408194
GA - InteriorWalls : : Model Lines : id 5169534
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3408194
GA - InteriorWalls : : Model Lines : id 5170192
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : Walls : Basic Wall : F410-GYP-3 5/8 : id 3536663
GA - InteriorWalls : : Model Lines : id 5169973
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ExteriorWalls : Walls : Curtain Wall : EWT-104 Precast Fins : id 4161004
GA - Floors : : Model Lines : id 4894125
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - Floors : Walls : Basic Wall : CON-101 Concrete in Situ 11 1/4" : id 4453670
GA - Floors : : Model Lines : id 4522613
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 4463799
GA - Floors : : Model Lines : id 4494678
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 4463799
GA - InteriorWalls : : Model Lines : id 5170310
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 4463907
GA - Floors : : Model Lines : id 4494678
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 4463907
GA - InteriorWalls : : Model Lines : id 5170310
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4540145
(Conference Biotech : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5322187
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4540145
(Conference Biotech : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5322470
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4540145
(Conference Biotech : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5430624
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4540147
(Conference Biotech : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5322069
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4540147
(Conference Biotech : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5323395
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - Floors : : Model Lines : id 4867001
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 5336934
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - Floors : : Model Lines : id 4867003
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5336912
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - Floors : : Model Lines : id 4867058
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5336912
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4914145
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5288384
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4914145
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5288901
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4914145
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5337080
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4914145
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5338514
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4914186
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Curtain Panels : Basic Wall : A420-GYP-3 5/8-GYP : id 5288425
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4914186
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Curtain Panels : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5288436
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4914215
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5288240
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4914215
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5288757
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4914215
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5336936
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 4914215
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5338379
A wall and a room separation line overlap. One of them may be ignored when Revit finds room boundaries. Shorten or delete the room separation line to remove the overlap. GA - InteriorWalls : : Model Lines : id 5180992
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5327798
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other or tab-select one of the grouped overlapping walls and exclude it from the group instance. GA - InteriorWalls : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 2800829
(BIOTECH : West_Option 2) : GA - Ceilings : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 3291185
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other or tab-select one of the grouped overlapping walls and exclude it from the group instance. GA - InteriorWalls : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 3027649
(BIOTECH : West_Option 2) : GA - Ceilings : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 3291182
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other or tab-select one of the grouped overlapping walls and exclude it from the group instance. GA - InteriorWalls : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 3027852
(BIOTECH : West_Option 2) : GA - Ceilings : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 3291183
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other or tab-select one of the grouped overlapping walls and exclude it from the group instance. GA - InteriorWalls : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 3027980
(BIOTECH : West_Option 2) : GA - Ceilings : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 3291184
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 590200
GA - InteriorWalls : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3536135
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - InteriorWalls : Walls : Basic Wall : D420-GSL-4-2xGYP : id 975539
GA - InteriorWalls : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 3020091
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 1729935
GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 3404871
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 1729939
GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 3404847
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : E200-CMU : id 1806649
GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 18" : id 2693026
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 1818332
GA - InteriorWalls : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3536135
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 1931848
GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2631328
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005180
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 5288238
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005180
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 5288755
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005180
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 5336934
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005180
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 5338377
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005181
(Offices 4th floor : Option 2) : GA - InteriorWalls : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 5244258
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005181
(Offices 4th floor : Option 3) : Workset1 : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 5276121
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005181
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5288754
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2005181
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5336933
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 2155195
(Conference Biotech : Option 2) : Workset1 : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 5322449
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - InteriorWalls : Walls : Basic Wall : A420-GYP-3 5/8-GYP : id 3020091
GA - InteriorWalls : Walls : Basic Wall : D420-GSL-4-2xGYP : id 3538059
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. GA - ExteriorWalls : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3408191
GA - ArchStructure : Walls : Basic Wall : CON-101 Concrete in Situ 12" : id 3408193
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309234
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326872
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309234
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326969
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309234
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5327066
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309234
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5433717
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309235
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326873
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309235
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326970
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309235
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5327067
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309235
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5327799
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309239
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326875
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309239
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326972
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309239
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5327069
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309240
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326876
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309240
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326973
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - Furniture : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309240
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5327070
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309253
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5329001
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309253
(ELI/EII OFFICE SUITE : Option 4) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5435251
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309254
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5285898
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309254
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : Generic 6" : id 5333814
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 4309255
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5285899
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 4309256
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 5285900
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 4309256
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 5286777
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 4309256
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : Generic 6" : id 5318810
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 4309256
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326877
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 4309256
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326974
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Immersive Telepresence Room : Option 1 - TX9000) : GA - InteriorWalls : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 4309256
(ELI/EII OFFICE SUITE : Option 1) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5327071
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Annex : Option 2) : GA - InteriorWalls : Walls : Basic Wall : F020-(2)GWB-7/8 : id 5211493
(Annex : Option 2) : GA - InteriorWalls : Walls : Basic Wall : F010-GWB-7/8 : id 5231734
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Annex : Option 2) : GA - InteriorWalls : Walls : Basic Wall : F020-(2)GWB-7/8 : id 5211500
(Annex : Option 2) : GA - InteriorWalls : Walls : Basic Wall : F010-GWB-7/8 : id 5212152
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Annex : Option 2) : GA - InteriorWalls : Walls : Basic Wall : F420-2xGYP-3 5/8 : id 5212044
(Annex : Option 2) : GA - InteriorWalls : Walls : Basic Wall : F010-GWB-7/8 : id 5231796
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (Annex : Option 2) : GA - InteriorWalls : Walls : Basic Wall : F020-(2)GWB-7/8 : id 5231781
(Annex : Option 2) : GA - InteriorWalls : Walls : Basic Wall : F010-GWB-7/8 : id 5231796
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Curtain Wall : Interior Glazed Partition type 3 : id 5286777
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326974
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : Generic 6" : id 5291224
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5326920
Highlighted walls overlap. One of them may be ignored when Revit finds room boundaries. Use Cut Geometry to embed one wall within the other. (ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Curtain Wall : Curtain Wall : id 5362793
(ELI/EII OFFICE SUITE : Option 3) : Workset1 : Walls : Basic Wall : A440-2xGYP-3 5/8-2xGYP : id 5362864
Insert conflicts with joined Wall. (ELI/EII OFFICE SUITE : Option 2) : Workset1 : Walls : Basic Wall : Generic 6" : id 5333814
(ELI/EII OFFICE SUITE : Option 2) : Workset1 : Doors : DOR_Sgl : W32", H84" (32"Leaf) - Mark S201UUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUU : id 5334000
Elements have duplicate 'Mark' values. Materials : Materials : Glass, Clear Glazing - Mark IGU-101 : id 123311
Materials : Materials : IGU-101 - Mark IGU-101 : id 4943822
Elements have duplicate 'Mark' values. Materials : Materials : CON-201 - Mark CON-201 : id 436463
Materials : Materials : Concrete, Precast - Mark CON-201 : id 449840
Elements have duplicate 'Mark' values. Materials : Materials : FLR-201 - Mark FLR-201 : id 436478
Materials : Materials : Floor Presentation - Mark FLR-201 : id 2044825
Elements have duplicate 'Mark' values. Materials : Materials : GYP-100 Gypsum - Dry Wall - Mark PNT-101 : id 436495
Materials : Materials : PNT-101 - Mark PNT-101 : id 436534
Elements have duplicate 'Mark' values. Materials : Materials : MAS-101 Masonry - CMU - Mark MAS-101 : id 436514
Materials : Materials : MAS-101 - Mark MAS-101 : id 436515
Elements have duplicate 'Mark' values. Materials : Materials : MTL-201 - Mark MTL-201 : id 436521
Materials : Materials : MTL-102 - Mark MTL-201 : id 4343070
Elements have duplicate 'Mark' values. GA - PlumbingFixtures : Plumbing Fixtures : PLU DrinkingFountainDblBottleFiller_2 : HTHB-HVRGRN8BL-NF - Mark 277 : id 2753142
GA - PlumbingFixtures : Plumbing Fixtures : Sink - Mop : 28"x28" - Mark 277 : id 2755846
Elements have duplicate 'Mark' values. GA - PlumbingFixtures : Plumbing Fixtures : PLU DrinkingFountainDblBottleFiller_2 : HTHB-HVRGRN8BL-NF - Mark 278 : id 2753330
GA - PlumbingFixtures : Plumbing Fixtures : Sink - Mop : 28"x28" - Mark 278 : id 2755847
Elements have duplicate 'Mark' values. GA - PlumbingFixtures : Plumbing Fixtures : PLU DrinkingFountainDblBottleFiller_2 : HTHB-HVRGRN8BL-NF - Mark 279 : id 2753378
GA - PlumbingFixtures : Plumbing Fixtures : Sink - Mop : 28"x28" - Mark 279 : id 2755848
Elements have duplicate 'Mark' values. Materials : Materials : MTL-101 - Mark MTL-101 : id 436519
Materials : Materials : Steel ASTM A53 - Mark MTL-101 : id 4196469
Materials : Materials : Steel ASTM A500, Grade B, Rectangular and Square - Mark MTL-101 : id 4196470
Elements have duplicate 'Mark' values. Materials : Materials : Default Wall - Mark CON-301 : id 24
Materials : Materials : CON-301 - Mark CON-301 : id 436465
Materials : Materials : Concrete, Cast-in-Place gray - Mark CON-301 : id 449841
Materials : Materials : CON-102 - Mark CON-301 : id 4548253
Elements have duplicate 'Number' values. Workset1 : Rooms : Room : ELEC 107 - Number 107 : id 652715
GA - InteriorWalls : Rooms : Room : ELEC 107 - Number 107 : id 4172717
Elements have duplicate 'Number' values. Workset1 : Rooms : Room : STORAGE 420 - Number 420 : id 2253886
Workset1 : Rooms : Room : STORAGE 420 - Number 420 : id 4154571
Elements have duplicate 'Type Mark' values. Type : Family : Doors : DOR_Sgl : Doors : DOR_Sgl : W36", H84" (36" Leaf) FireDoor : id 555523
Type : Family : Doors : Door-Curtain-Wall-Double-Glass : Doors : Door-Curtain-Wall-Double-Glass : Door-Curtain-Wall-Double-Glass : id 562071
Elements have duplicate 'Type Mark' values. Type : Family : Detail Items : GYP Ceiling 2 : Detail Items : GYP Ceiling 2 : GYP Ceiling 2 : id 3918553
Type : Family : Detail Items : Metal Dropped Ceiling : Detail Items : Metal Dropped Ceiling : Metal Dropped Ceiling : id 4685631
Elements have duplicate 'Type Mark' values. Type : Family : Curtain Panels : System Panel : Curtain Panels : System Panel : Precast Panel 6" : id 4082002
Type : Family : Curtain Panels : CUR_Fin_Center : Curtain Panels : CUR_Fin_Center : CUR_Fin_Center : id 4162555
Elements have duplicate 'Type Mark' values. Type : Curtain Wall Types : Walls : Curtain Wall : CW Play : id 4201279
Type : Curtain Wall Types : Walls : Curtain Wall : LUV-101 Louver System : id 4222870
Elements have duplicate 'Type Mark' values. Type : Sloped Glazing Types : Roofs : Sloped Glazing : CMP-101 Non Insulated Composite Panel : id 4416724
Type : Sloped Glazing Types : Roofs : Sloped Glazing : EWT-105 : id 4866710
Elements have duplicate 'Type Mark' values. Type : Family : Doors : DOR_CW Sgl Glass framed : Doors : DOR_CW Sgl Glass framed : Frame Head & Sill : id 4680927
Type : Family : Doors : Door-Curtain-Wall-Double-Storefront : Doors : Door-Curtain-Wall-Double-Storefront : Door-Curtain-Wall-Single Storefront : id 4686964
Elements have duplicate 'Type Mark' values. Type : Family : Doors : DOR_CW Sgl Glass framed : Doors : DOR_CW Sgl Glass framed : Frame 4 sides : id 4680929
Type : Family : Doors : DOR_Sgl_Framed : Doors : DOR_Sgl_Framed : DOR_Sgl_Framed : id 4689893
Elements have duplicate 'Type Mark' values. Type : Family : Detail Items : Family1 : Detail Items : Family1 : Family1 : id 3708588
Type : Family : Detail Items : Metal Cladding Pop-Out Bottom : Detail Items : Metal Cladding Pop-Out Bottom : Metal Cladding Pop-Out Bottom : id 3914025
Type : Family : Detail Items : Metal Panel : Detail Items : Metal Panel : 2" : id 4051901
Elements have duplicate 'Type Mark' values. Type : Family : Detail Items : Tension Mesh Top : Detail Items : Tension Mesh Top : 07_4120_Metal Panel_Curb : id 4014276
Type : Family : Detail Items : Tension Mesh Center : Detail Items : Tension Mesh Center : 07_4120_Metal Panel_Curb : id 4015947
Type : Family : Detail Items : Tension Mesh Bottom : Detail Items : Tension Mesh Bottom : 07_4120_Metal Panel_Curb : id 4016630
Elements have duplicate 'Type Mark' values. Type : Family : Curtain Panels : CUR_RotationPanel : Curtain Panels : CUR_RotationPanel : 35deg : id 4201270
Type : Family : Curtain Panels : CUR_RotationPanel : Curtain Panels : CUR_RotationPanel : 45deg : id 4201271
Type : Family : Curtain Panels : CUR_RotationPanel : Curtain Panels : CUR_RotationPanel : 15deg : id 4201280
Elements have duplicate 'Type Mark' values. Type : Family : Curtain Panels : CUR_Spandrel : Curtain Panels : CUR_Spandrel : SPN-101 : id 2153504
Type : Family : Curtain Panels : CUR_Spandrel_CornerInRT : Curtain Panels : CUR_Spandrel_CornerInRT : CUR_Spandrel_CornerInRT : id 3473462
Type : Family : Curtain Panels : CUR_Spandrel_CornerInR : Curtain Panels : CUR_Spandrel_CornerInR : CUR_Spandrel_CornerInR : id 3478177
Type : Family : Curtain Panels : CUR_SpandrelTop : Curtain Panels : CUR_SpandrelTop : SPN-101 : id 4291435
Elements have duplicate 'Type Mark' values. Type : Wall Types : Walls : Basic Wall : EWT-105 Metal Panel : id 4222867
Type : Wall Types : Walls : Basic Wall : EWT-105 Metal Panel - Penthouse : id 4226384
Type : Wall Types : Walls : Basic Wall : EWT-105 Metal Panel - 12" : id 4232974
Type : Curtain Wall Types : Walls : Curtain Wall : EWT-105 Penthouse : id 4323588
Elements have duplicate 'Type Mark' values. Type : Floor Types : Floors : Floor : Generic - 7" : id 2043620
Type : Floor Types : Floors : Floor : Generic - 8" : id 3651892
Type : Floor Types : Floors : Floor : EWT-105 Metal Panel : id 4222369
Type : Floor Types : Floors : Floor : EWT-105 Metal Panel - 4" : id 4226335
Type : Floor Types : Floors : Floor : EWT-105 Metal Panel - Bottom : id 4321109
Elements have duplicate 'Type Mark' values. Type : Family : Detail Items : 07_2100 Rigid Insulation-Section : Detail Items : 07_2100 Rigid Insulation-Section : 2" : id 3564727
Type : Family : Detail Items : 07_2100_Rigid_Insulation_Section : Detail Items : 07_2100_Rigid_Insulation_Section : 2" : id 3570196
Type : Family : Detail Items : 07_1326_Rigid_Insulation_Below_Grade : Detail Items : 07_1326_Rigid_Insulation_Below_Grade : 3" : id 4216010
Type : Family : Detail Items : 07_2100_Rigid_Insulation_Section : Detail Items : 07_2100_Rigid_Insulation_Section : 2 1/2" : id 4264497
Type : Family : Detail Items : 07_2100_Rigid Insulation-Tapered-Section : Detail Items : 07_2100_Rigid Insulation-Tapered-Section : INS-101 : id 4865989
The Actual Run Width of one or more runs is less than the Minimum Run Width specified in the stair type. GA - StairsRailings : Runs : Non-Monolithic Run : Glass Treads : id 1973282
The Actual Run Width of one or more runs is less than the Minimum Run Width specified in the stair type. GA - StairsRailings : Runs : Non-Monolithic Run : Glass Treads : id 1973864
The Actual Tread Depth of stair is less than the Minimum Tread Depth specified in the stair type. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 3038885
The Actual Tread Depth of stair is less than the Minimum Tread Depth specified in the stair type. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 3412541
Stair bottom end exceeds or cannot reach the base elevation of the stair. Add/remove risers at the bottom end by control or change the stair run's 'Relative Base Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4485314
Stair bottom end exceeds or cannot reach the base elevation of the stair. Add/remove risers at the bottom end by control or change the stair run's 'Relative Base Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4485490
Stair bottom end exceeds or cannot reach the base elevation of the stair. Add/remove risers at the bottom end by control or change the stair run's 'Relative Base Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4485528
Stair bottom end exceeds or cannot reach the base elevation of the stair. Add/remove risers at the bottom end by control or change the stair run's 'Relative Base Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4492488
Stair bottom end exceeds or cannot reach the base elevation of the stair. Add/remove risers at the bottom end by control or change the stair run's 'Relative Base Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4492521
Stair bottom end exceeds or cannot reach the base elevation of the stair. Add/remove risers at the bottom end by control or change the stair run's 'Relative Base Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4492552
Stair bottom end exceeds or cannot reach the base elevation of the stair. Add/remove risers at the bottom end by control or change the stair run's 'Relative Base Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4492579
Stair components are not continuously connected. This may cause incorrect representation and annotation. GA - InteriorWalls : Stairs : Assembled Stair : Stair : id 4833970
Stair top end exceeds or cannot reach the top elevation of the stair. Add/remove risers at the top end by control or or change the stair run's 'Relative Top Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4485314
Stair top end exceeds or cannot reach the top elevation of the stair. Add/remove risers at the top end by control or or change the stair run's 'Relative Top Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4485490
Stair top end exceeds or cannot reach the top elevation of the stair. Add/remove risers at the top end by control or or change the stair run's 'Relative Top Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4485528
Stair top end exceeds or cannot reach the top elevation of the stair. Add/remove risers at the top end by control or or change the stair run's 'Relative Top Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4492488
Stair top end exceeds or cannot reach the top elevation of the stair. Add/remove risers at the top end by control or or change the stair run's 'Relative Top Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4492521
Stair top end exceeds or cannot reach the top elevation of the stair. Add/remove risers at the top end by control or or change the stair run's 'Relative Top Height' parameter in the properties palette. GA - StairsRailings : Stairs : Cast-In-Place Stair : Stair : id 4492552